Calculate the RL time constant τ = L/R or the current at time t as it grows toward its final value or decays from its starting value.
How to use
How it works
An inductor opposes changes in current, so current builds gradually after a switch closes. In one time constant it reaches 63.2% of its final value; on decay it falls to 36.8%. A bigger inductance or smaller resistance slows the change.
τ = L ÷ R growth: I = I∞(1 − e^(−t/τ)) decay: I = I₀ e^(−t/τ)
Worked example
Growth over one time constant
- Input
- R = 10 Ω, L = 2 H, t = 0.2 s, I∞ = 1 A
- Output
- τ = 0.2 s; I = 0.63212 A
- Walkthrough
- τ = 2 ÷ 10 = 0.2 s. I = 1 × (1 − e⁻¹) = 0.63212 A; decay from 1 A gives 0.36788 A.